R3554 Data Sheet: R3554.pdf |
Video Isolation Transformer
- Video Hum Elimination for CCTV applications
- RoHS Compliant Product
- Operating Temperature: 0°C to +70°C
- Hipot: 500VDC, 1KMW (connector to connector, connectors to case)
- Ground isolation (50/60 Hz): 90 dB
- Custom design available on request
|
|
|
R3532 R3542 Data Sheet: R3532/ R3542.pdf |
Video Isolation Transformer
- RoHS Compliant Product
- Operating Temperature: 0°C to +70°C
- Hipot: 250VDC, 1KMW, (Pri to Sec)
- Polarity: 1 and 6 are in phase
- Custom design available on request
|
|
|
R3536 Data Sheet: R3536.pdf |
Mini Video Isolation Transformer
- For CCTV ground isolation and hum stopping
- RoHS Compliant Product
- Operating Temperature: 0°C to +70°C
- CMR: -80dB Typical 50/60Hz
- Hipot: 250VDC, 1KMW, (Pri to Sec)
- Polarity: 1 and 6 are in phase
- Custom design available on request
|
|
|
R3600 Data Sheet: R3600.pdf |
Wide Band Isolation Transformer
- For RF, DS3/E3, Broadband, BPL, and Ethernet magnetics which require supplementary or reinforced isolation
- Construction complies with IEC60950 isolation requirements
- Operating Temperature: 0°C to +70°C (extended temperature subject to request)
- RoHS compliant product
|
|
|
R12702 Data Sheet: R12702.pdf |
Pulse Transformer (SO16 Package)
- RoHS Compliant Product
- Hipot : 2,000VRMS Primary to Secondary
- Turns Ratio : 1 : 1 ±2%
- Rise Time: 3.0 nS Max
- Primary ET: 2.7V-µSec Min
- OCL, LL, CWW are measured @ 100KHz, 20mV
- Operating Temp : -40°C to +85°C
|
|
|
R12703 Data Sheet: R12703.pdf |
Pulse Transformer (DIP16 Package)
- RoHS Compliant Product
- Hipot : 500VRMS Primary to Secondary
- Turns Ratio : 1 : 1 ±2%
- Rise Time: 3.5 nS Max
- OCL, LL, CWW are measured @ 100KHz, 100mV
- Operating Temp : -40°C to +85°C
|
|
|
R12704 Data Sheet: R12704.pdf |
Pulse Transformer (TC2 Package)
- RoHS Compliant Product
- LL, CWW are measured @ 100KHz, 20mV
- Operating Temp : 0°C to 70°C
|
|